September 27, 2010
We received an interesting question about pre-rigged systems from one of our subscribers. The TechPanel had some helpful comments to share, so we have re-posted the info here. It’s a great topic. Things to consider about leaving systems pre-rigged First of all, whether to pre-rig systems or not depends a lot on the types of...
Read More
September 24, 2010
This question was submitted by Thomas Vitti from the Chevron Fire Dept. in Salt Lake City, Utah. In the event of an actual rescue is a safety line necessary? Good question… the answer is YES and NO. This question falls into somewhat of a gray area. Much depends on what type of rescue you’re doing;...
Read More
September 1, 2010
Reader Jeff Machen had a question concerning how much training to give attendants on air monitoring equipment; especially when they may only be working a week long shut down? Here’s our reply from CSRT Manager Bryan Rogers. When you’re dealing with temporary labor, it is difficult to ensure that they are well trained on something...
Read More
August 26, 2010
“Most likely the loaded section of the line is catching on the anti-error catch where the load line enters the body of the ID. This is a safety feature of the ID to prevent free-falling loads if the ID is loaded backwards. To prevent the rope from jamming, consider positioning yourself between the ID and...
Read More
August 25, 2010
The answer may be in the description “trusty old”. The ID has a wear indicator cast into the friction bobbin. It is located at the top of the bobbin on the side of the bobbin that the swinging side plate is on. When in usable condition the wear indicator is visible as a slightly raised...
Read More
August 19, 2010
Several of the current electro/mechanical CO sensors will give a false indication of CO when exposed to solvents and especially when exposed to isopropyl alcohol. If the potential for CO presence can be definitively ruled out, consider using an atmospheric monitor with no CO sensor.
Read More
July 27, 2010
Recently, we had a client ask about these specific uses of the Sked-EVAC tripod. Here’s what the manufacturer (Skedco) had to say… “Is it safe to attach a ‘change of direction’ onto the lower end of one of the tripod legs?” “No!” According to Bud Calkin, the manufacturer of the tripod. He continues in saying...
Read More
July 1, 2010
Yes, with a couple of extra precautions.
Read More
June 24, 2010
The three levels of protection required by OSHA for confined space entrants are: 1) Hazard Awareness
Read More
June 9, 2010
Yes. A retrieval system should be used whenever an entrant enters a permit space, unless the retrieval system creates a greater hazard to the entrant or does not contribute to the rescue effort.
Read More